Filter Results By:

Products

Applications

Manufacturers

Showing results: 136 - 150 of 277 items found.

  • 12-Channel ADC Module

    FMC112 - Sundance Multiprocessor Technology Ltd.

    The FMC112 is a twelve-channel ADC FMC Daughter Card which is fully compliant with the VITA 57.1-2008 standard. The FMC112 provides twelve A/D 14-bit 125Msps channels which can be sampled by an internal clock source (optionally locked to an external reference) or an externally supplied sample clock. A trigger input for customized sampling control is also available. The FMC112 has the LPC (Low-Pin Count) connector, front panel I/O, and is conduction cooled capable.

  • 16-Channel ADC Module

    FMC116 - Sundance Multiprocessor Technology Ltd.

    The FMC116 is a sixteen-channel ADC FMC Daughter Card which is fully compliant with the VITA 57.1-2008 standard. The FMC116 provides sixteen A/D 14-bit 125Msps channels which can be sampled by an internal clock source (optionally locked to an external reference) or an externally supplied sample clock. A trigger input for customized sampling control is also available. The FMC116 has the HPC (high-pin count) connector, front panel I/O, and is conduction cooled capable.

  • 2-Channel DAQ Module

    FMC151 - Sundance Multiprocessor Technology Ltd.

    The FMC151 is a dual channel ADC and dual channel DAC FMC daughter card. The card provides two 14-bit A/D channels and two 16-bit D/A channels which can be clocked by an internal clock source (optionally locked to an external reference) or an externally supplied sample clock. In addition there is one trigger input for customized sampling control. The FMC151 daughter card is mechanically and electrically compliant to the FMC standard (ANSI/VITA 57.1).

  • 2-Channel DAQ Module

    FMC150 - Sundance Multiprocessor Technology Ltd.

    The FMC150 is a dual channel ADC and dual channel DAC FMC daughter card. The card provides two 14-bit A/D channels and two 16-bit D/A channels which can be clocked by an internal clock source (optionally locked to an external reference) or an externally supplied sample clock. In addition there is one trigger input for customized sampling control. The FMC150 daughter card is mechanically and electrically compliant to the FMC standard (ANSI/VITA 57.1).

  • Portable Three-Phase Meter Site Analyzer

    RW-30X / RW-31X - Radian Research, Inc.

    RADIAN RW-30/31X Meter Site Analyzers deliver comprehensive three-phase field testing and site analysis utilizing the Radian Research RX Xytronic series reference standard as its measurement engine. The RW-30/31X provides for testing meters with integrated, precision, true three-phase voltage and current sources or using customer’s load. Choose the RW-30/31X NS (no source) model to test using customer’s load only.

  • Room Temperature Sample Holders

    12962A - Ametek Scientific Instruments

    The 12962A sample holder is designed to allow accurate impedance tests of solid materials to be performed at room temperature. The sample holder consists of two parallel electrodes, one of which is fixed in position and the other which can be moved into contact with the sample by adjustment of a micrometer. The sample holder makes use of guard ring and reference techniques in order to improve accuracy by reducing “fringing” effects at the edge of the sample. The standard electrode provided is 20mm diameter.

  • Reference Thermapen®

    ThermoWorks

    Until now you would have spent hundreds more to get this level of accuracy in a NIST-Traceable standards thermometer. Our Reference Thermapen takes lab accuracy into the field. Each unit is factory calibrated at 5 test points and includes a UKAS accredited calibration certificate with test data. A true "system calibration" is performed matching its Platinum RTD sensor and the built-in electronics so all errors are included in the spec.

  • LC/MS/MS Method Package For Water Quality Analysis

    Shimadzu Corp.

    Shimadzu provides method files, including pre-registered MRM parameters with optimized quantitative and reference ions, LC separation parameters, and retention times and peak identification parameters for each compound, as well as report templates for outputting quantitation results, as a package. If retention times are adjusted when the system is introduced, based on the HPLC configuration delivered, the analysis process can be started as soon as the specified columns, mobile phases, and standard samples are supplied.

  • Hydrogen Frequency & Time Standard

    CH1-1033 - VREMYA-CH JS Company

    The hydrogen frequency and time standard Ch1-1033 is designed for precision storage and reproduction of the size of frequency and time units as part of measures and reference complexes. Main areas of application: – public service of time and frequency; – ground control complexes of radio navigation systems; – radio interferometry with extra long base.

  • Fully Automatic Colorimeter

    DRK103C - Shandong Drick Instruments Co., Ltd.

    (1)5 inch TFT color LCD touch screen, the operation is more humanized, new users can be mastered in a short period of time using the method.(2)Simulation of D65 lighting lighting, using CIE1964 complementary color system and CIE1976 (L*a*b*) color space color difference formula.(3)The motherboard brand new design, using the latest technology, CPU uses 32 bits ARM processor,improve the processing speed, the calculated data is more accurate and rapid electromechanical integration design, abandon cumbersome testing process of the artificial hand wheel is rotated, the real implementation of the test program, a determination of the accurate and efficient.(4)Using d/o lighting and observation geometry, diffuse ball diameter 150mm, diameter of the testing hole is 25mm.(5) A light absorber, eliminate the effect of specular reflection.(6)Add printer and imported thermal printer, without the use of ink and color, no noise when working, fast printing speed.(7) Reference sample can be physical, but also for data,? Can store up to ten only memory reference information.(8) Has the memory function, even if the long-term shutdown loss of power, memory zeroing, calibration, standard sample and a reference sample values of the useful information is not lost.(9) Equipped with a standard RS232 interface, can communicate with computer software.

  • 60 GHz WR-15 Waveguide Tx Module

    PEM010 - Pasternack Enterprises, Inc.

    The PEM010 is a highly integrated millimeter wave transmitter that covers the 60 GHz global unlicensed spectrum allocations packaged in a standard waveguide module. Transmitter architecture is a double conversion, sliding IF with wide bandwidth capability through the up-conversion chain from baseband to carrier. The I/Q interface accepts analog baseband signals which provides for flexibility in design and applications. The baseband input optionally supports FSK/MSK modulation for non-coherent applications. The transmitter incorporates a complete waveguide interface with low-loss transition between the chip and the WR15 waveguide port. The integrated package is small and lightweight, with a simple to use multi-pin ST4 connector for power, reference clock, digital control port and baseband signals. Either of two reference clocks can be used for setting 540 MHz or 500 MHz channel spacing.

  • Active Type Hydrogen Frequency

    CH1-1003M - VREMYA-CH JS Company

    Hydrogen frequency and time standard Ch1-1003M is designed for precision storage and reproduction of the size of frequency and time units as part of measures and reference complexes. Main applications: – national time and frequency services; – ground stations for tracking and control of satellite radio navigation systems; – radio interferometry with extra long base.

  • 4-Channel DAC FMC Module

    FMC204 – HPC - Sundance Multiprocessor Technology Ltd.

    The FMC204 is a quad channel DAC FMC. The FMC204 provides four channels of 16-bit D/A @ 1 GSPS enabling simultaneous sampling at a maximum rate of 1 GSPS. The sample clock can be supplied externally through a coax connection or supplied by an internal clock source (optionally locked to an external reference). Additionally a trigger input for customized sampling control is available. The FMC204 daughter card is mechanically and electrically compliant to FMC standard (ANSI/VITA 57.1).

  • RF Testing & Engineering Services

    RF Testing & Engineering Services - 360°RF

    Our team has world-class radio frequency experience in defense contracting, design, engineering, manufacturing, quality, research, and testing. The staff at 360°RF includes numerous design patent holders, a sitting member of the CEA's (Consumer Electronics Assoc.) Standards Committee, as well as columnists, editors, and authors for trade publications and reference books, including Radio Shack, Antennas, Selection, Installation, and Projects, TV, FM, CB, Cellular, Satellite, and Shortwave.

  • FMC Loopback Test Board

    Kaya Instruments

    The FMC loopback tester board enables developers and assembly factories to test and characterize the FMC carrier board interfaces. The board features full differential loopbacks on all the FMC high pin count (HPC) connector interfaces including LA, HA, HB, DP and CLK. It also provides a 125MHz transceiver LVDS reference clocks on GBTCLK signals. The FMC loopback board is based on VITA 57 standard with ruggedized conduction or air cooling.

Get Help